1.
Biosensors (Basel) ; 12(9)2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36140083

RESUMO

The present work describes the development of an easy-to-use portable electrochemical biosensor based on alkaline phosphatase (ALP) as a recognition element, which has been immobilized in acrylamide-based hydrogels prepared through a green protocol over disposable screen-printed electrodes. To carry out the electrochemical transduction, an electroinactive substrate (hydroquinone diphosphate) was used in the presence of the enzyme and then it was hydrolyzed to an electroactive species (hydroquinone). The activity of the protein within the matrix was determined voltammetrically. Due to the adhesive properties of the hydrogel, this was easily deposited on the surface of the electrodes, greatly increasing the sensitivity of the biosensor. The device was optimized to allow the determination of phosphate ion, a competitive inhibitor of ALP, in aqueous media. Our study provides a proof-of-concept demonstrating the potential use of the developed biosensor for in situ, real-time measurement of water pollutants that act as ALP inhibitors.


Assuntos
Técnicas Biossensoriais , Poluentes da Água , Acrilamida , Fosfatase Alcalina , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos , Hidrogéis , Hidroquinonas , Fosfatos